Customization: | Available |
---|---|
Task: | 12V to 28V 30A 840W DC-DC Converter, Non-Isolated |
Structure: | Non-Isolated |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
model | input voltage range (Vdc) |
output voltage (Vdc) |
output current typ (A) |
output power max (W) |
ripple and noise typ (mVp-p) |
efficiency typ ( % ) |
H30-12-28 | 11-16 | 28 | 30 | 840 | 120 | 95 |
Parameter | Test conditions or description | Min | Typ | Max | Units |
operating input voltage | 12 V input | 11 | 12 | 16 | Vdc |
Parameter | Test conditions or description | Min | Typ | Max | Units |
line regulation | measured from high line to low line | ±0.2 | % | ||
load regulation | measured from full load to zero load | ±0.2 | % | ||
voltage accuracy | ±1.5 | % | |||
adjust range | 27.95 | 28 | 28.05 | V | |
temperature coefficient | ±0.03 | %/°C |
Parameter | Test conditions or description | Min | Typ | Max | Units |
output over voltage protection | %Vo | 115 | 140 | % | |
short circuit protection | Continuous | ||||
current limit | % nominal output current | 105 | 110 | 125 | % |
thermal shutdown case temp. | 85 | °C | |||
cooling | free air convection | ||||
fuse | built in PCB | 80 | A |
Parameter | Test conditions or description | Min | Typ | Max | Units |
safety approvals | EN 61000-6-3:2007/A1:2011/AC:2012 EN 55014-1:2006/A2:2011 EN 60950-1:2006/AC:2011 |
||||
enclosures | IP68 |
Parameter | Test conditions or description | Min | Typ | Max | Units |
case operating temperature | -40 | 25 | 85 | °C | |
Ambient temperature | -20 | 60 | °C | ||
storage temperature | -40 | 105 | °C | ||
humidity | non-condensing | 95 | % |
Parameter | Test conditions or description | Min | Typ | Max | Units |
dimensions ( L x W x H ) | (180*127*63mm) | MM | |||
wire length | 18 | cm | |||
case material | aluminum | ||||
weight | 1800 | grams | |||
Package | 1pcs/box, 12pcs/carton | ||||
Carton measurement | 46.5*31.3*32.8cm | cm |